The Infinity Pump is a portable enteral feeding system designed for pediatric and adult patients, delivering nutrition solutions at selectable rates. It is a rotary peristaltic pump.
1.1 What is the Infinity Pump?
The Infinity Pump is a portable, rotary peristaltic enteral feeding system designed to deliver nutrition solutions at programmable rates. It is intended for use by pediatric and adult patients requiring enteral nutrition. The pump is compact, lightweight, and user-friendly, making it ideal for both home and clinical settings. Its design ensures precise delivery of feeding solutions, promoting patient comfort and mobility.
1.2 Purpose and Applications
The Infinity Pump is designed to deliver enteral nutrition solutions to pediatric and adult patients who require nutritional support. Its primary purpose is to provide accurate and consistent feeding at programmable rates. Common applications include home care, hospitals, and clinical settings. The pump’s portability and user-friendly design make it suitable for both stationary and mobile use, ensuring patients receive the necessary nutrition in various environments.
Key Components of the Infinity Pump
The Infinity Pump features a display for monitoring settings, intuitive controls for operation, rear connectors for power and accessories, and additional components for safe and efficient use.
2.1 Display and Controls
The Infinity Pump features a clear display with large alphanumeric characters and symbols for easy monitoring of settings and messages. The intuitive controls include buttons for navigating menus, adjusting rates, and managing feeding schedules. The display also shows real-time updates, ensuring precise operation and patient safety. These components are designed for user-friendly interaction, making it simple to program and monitor feeding sessions effectively.
2.2 Rear Components and Connectors
The rear of the Infinity Pump includes essential components for functionality and connectivity. Key features are the serial number label, charger/power connector, receptacle for pole clamp attachment, and a speaker for auditory alerts. These components ensure proper operation, mounting, and power supply. The charger port is located on the left side for convenient access. These elements are designed to support seamless integration and reliable performance in various clinical settings.
2.3 Additional Features and Accessories
The Infinity Pump includes advanced features such as programmable set points, an integrated programmer, and optional Bio-Inert technology for precise fluid delivery. Accessories like feeding sets, bags, and chargers enhance functionality. The pump is compatible with specific feeding tubes and bags, ensuring reliable operation; These features and accessories are designed to meet diverse patient needs and provide accurate nutrition delivery in clinical and home settings.
Installation and Preparation
Installation involves attaching the pump clamp and charging via the designated port. Ensure all components are securely connected before first use.
3.1 Attaching the Pump Clamp
To attach the pump clamp, insert the small clamp screw into the opening on the backside of the Infinity pump. Turn the gray wheel to tighten the screw. Ensure it is snug but avoid overtightening, as this may damage the pump. Properly securing the clamp ensures stability during operation. Follow the manufacturer’s guidelines for correct installation to maintain pump functionality and safety.
3.2 Charging the Pump
To charge the Infinity pump, insert the flat end of the charger into the designated port on the left side of the device. Ensure the charger is fully connected to a power source. The pump’s indicator light will show charging status. Allow 6 hours for a full charge. Avoid overcharging to maintain battery longevity. Always use the provided charger to prevent damage. Keep the pump upright while charging for optimal performance.
Operating the Infinity Pump
The Infinity pump delivers enteral nutrition solutions efficiently. Its intuitive design allows for easy setup and operation, ensuring accurate feeding rates and patient comfort always.
4.1 Priming the Pump
Priming the Infinity pump ensures proper operation by removing air from the tubing. Loop the silicone tubing around the pump wheel, stretching it slightly. Once the pump detects the tubing, it will begin the priming process automatically. A green light or audible beep will confirm completion. Always prime the pump before starting a feeding session to ensure accurate delivery of nutrition solutions. This step is crucial for patient safety and pump performance.
4.2 Setting Up the Feeding Tube
To set up the feeding tube, remove the protective cover from the connector and insert it into the pump’s designated port. Ensure the connector is securely locked to prevent dislodgment. Properly align the tubing with the pump’s wheel to ensure accurate delivery. Always verify the tubing is correctly seated before starting the pump. This step ensures precise nutrition delivery and prevents complications. Follow the manual for detailed guidance.
Safety Considerations
Always use the Infinity Pump as described in the manual. Ensure only prescribed feeding solutions are used and avoid improper modifications. Keep it away from extreme temperatures and moisture. Adhere to electromagnetic environment guidelines to prevent interference. Regularly inspect for damage and follow proper cleaning procedures to maintain safety and functionality.
5.1 Warnings and Cautions
Always use the Infinity Pump as described in the manual. Only use feeding solutions prescribed by a physician. Avoid improper modifications or unauthorized repairs. Keep the pump away from flammable gases and extreme temperatures. Ensure the environment complies with electromagnetic disturbance guidelines. Never submerge the pump in water or expose it to excessive moisture. Regularly inspect for damage and follow proper cleaning procedures to ensure safe operation. Adhere to all warnings to prevent accidents and maintain functionality.
5.2 Environmental Use Guidelines
The Infinity Pump is designed for use in environments with controlled electromagnetic disturbances. Avoid exposing the pump to extreme temperatures (below 41°F or above 104°F) and high humidity levels. Keep it away from flammable gases and vapors. Do not operate in high-vibration areas. Ensure the environment complies with the pump’s electromagnetic compatibility standards. Non-compliance may affect performance or safety. Always follow these guidelines to maintain optimal functionality and user safety.
Troubleshooting Common Issues
This section addresses common malfunctions and provides solutions for the Infinity Pump. Identify alarms, resolve pump errors, and restore functionality efficiently with guided troubleshooting steps.
6.1 Identifying Alarm Conditions
The Infinity Pump features alarms to indicate operational issues. Common alarms include low battery, blockage detection, or improper tubing connections. Each alarm is accompanied by specific sounds or messages on the display. Users should refer to the manual for detailed explanations of alarm conditions and their corresponding solutions. Addressing these issues promptly ensures continuous and safe operation of the pump. Always follow the troubleshooting guide to resolve problems efficiently.
6.2 Resolving Pump Malfunctions
If the Infinity Pump malfunctions, first check for common issues like kinked tubing, blockages, or loose connections. Ensure all components are securely attached and properly aligned. Restarting the pump or resetting settings may resolve the issue. For persistent problems, consult the troubleshooting guide or contact customer support. Always refer to the manual for specific instructions on addressing and resolving pump malfunctions effectively; Regular maintenance can help prevent such issues.
Maintenance and Care
Regular cleaning and proper storage are essential for maintaining the Infinity Pump’s performance. Follow the manual’s guidelines for cleaning and storage procedures to ensure longevity.
7.1 Cleaning the Pump
To maintain the Infinity Pump’s functionality, clean it regularly. Use a damp cloth to wipe the exterior, avoiding harsh chemicals or submerging it in water. Ensure all surfaces are dry after cleaning. For internal components, follow the manual’s specific instructions to prevent damage. Regular cleaning prevents contamination and ensures accurate operation. Always refer to the manual for detailed cleaning procedures to maintain the pump’s performance and longevity.
7.2 Storing the Pump
When not in use, store the Infinity Pump in a cool, dry place, away from direct sunlight and moisture. Ensure the pump is fully charged or disconnected from power sources. Use a protective cover to prevent dust accumulation. Avoid extreme temperatures and physical stress. Proper storage maintains the pump’s performance and extends its lifespan. Always follow the manual’s guidelines for storage conditions to ensure optimal functionality when reused.
Accessories and Compatibility
The Infinity Pump is compatible with a range of accessories, including feeding sets, bags, chargers, and power options, ensuring optimal performance and convenience for enhanced functionality.
8.1 Feeding Sets and Bags
The Infinity Pump is compatible with specific feeding sets and bags designed for enteral nutrition. These sets ensure accurate delivery of nutrition solutions. Always use genuine accessories to maintain performance and safety. The feeding sets are crafted to connect seamlessly with the pump, minimizing the risk of leaks or blockages. Proper fit and function are essential for reliable operation. Follow the manual’s instructions for connecting and using feeding sets and bags.
8.2 Chargers and Power Options
The Infinity Pump comes with a rechargeable battery and a compatible charger. The charger connects to the designated port on the pump’s side. A full charge typically takes around six hours. Always use genuine chargers to ensure proper function and safety. The pump can also operate while charging, providing continuous use. For optimal performance, avoid using non-compatible chargers, as they may damage the device. Genuine accessories are recommended.